Home  |  FAQs  |  Send Enquiries Search For      Shopping cart  .  ภาษาไทย  
  Main Menu
Share with us on the FACEBOOK
Web Board
News
Interesting Links
Products & Services
 
  Products & Services
Industrial Gases
Medical Gases
Calibration Gases / Standard Gases
Cryogenic Tank , Liquid Nitrogen Dewar
Fluorocarbons and Rare Gases
Gases Handling Equipment
Gas Leak Detector and Gas Analyser
Pressure Gauge and Gas Flow Control
Chemical Gases and Material Science
Industrial Supply & MRO Products
Installation & Facility Service
Fuel Cell & Energy
 
  Interesting Links
Share with us on the FACEBOOK
Biogas , Bio-Methane, LNG, New Fueling
Hydrogen Storage
Fuel Cell Technology
Piping, Engineering, Fire Suppression System
HVAC&R , Heat, Ventilation, Air Conditioner, Refrigerant
Refrigerant Gas, Foaming Agent, Cleaning Agent, Insulation
PROCAP - Rubber and Plastic Elements for Every Application
Techstore Industrial Supply & MRO
 

Products & Services

Category: Top / Gas Leak Detector and Gas Analyser / Biogas Analyser - for Ethanol Plant and Sewage gas Plant

Biogas Analyser - Online Gasboard 3200L

More Details >>> 

Product Brief: 
- Multi-component gas measurement with Proprietary
  Infrared(NDIR) gas sensor long lifetime electrochemical
  gas sensor. 
- measure gas concentration of CH4,CO2,H2S,O2 from
  process of landfill and other industry. 
- LCD(240~128). 
- optional built-in sampling pump. 
- RS-232 interface 
- Supply data sample control Software for Demo

Biogas Analyser - Portable Gasboard 3200P

More Details >>> 


BioGas Analyser CHEMEC BC-20

MoreDetails >>

            The measuring device for CH4, CO2, O2 and H2S in biogas , landfill and sewage gas Robust and very exact metrology Visualization of the measurement-values Low maintenance with our calibration unit Ca20 Biogas Controller BC20 determines the concentrations of methane (CH4), carbon dioxide (CO2), oxygen (CO2) and hydrogen sulphide (H2S) in biogas. CH4, CO2 and CO2 are continuously measured every 5 minutes.

             The time interval between two H2S -measurements can be adapted to the requirements, from 30 minutes to 12 hours. Additionally, the measurement of H2S can also be triggered or switched off by the SPS.

             The CH4, CO2 and CO2 concentrations are determined with a combination of thermal conductivity-sensor and electro-chemical O2 sensor.

             The integrated data-logger stores 500 datasets. A dataset consists of date, time, measurement data, measuring point as well as error messages.

             The user can modify the storage intervals at levels that are preset. The graphical display represents the time- progression of the gas quality based on the last 500 measurements. BC20 is fully compatible to the SUSI data-acquisition system.

             A stainless-steel flame-trap and an air-filter are part of delivery. Measuring range Methane 0 to 100 Volume % Carbon dioxide 0 to 100 Volume % Oxygen 0 to 20.9 Volume % Hydrogen sulphide 0 to 2,000 ppm Display of measurement-values Numerical current measurement-values Graphical time-progression of the measurement-values


Infrared Gas Sensor Module for analysis of CH4, CO2

more details>> 

Gas sensor with infrared detection technology (NDIR) Dual Beam Highly reliable LEL monitorring Settable alarm thresholds  Bus-capable (modbusprotocol) Lifetime > 10 Years General features

Gas detected : Carbon Dioxide CO2

Detection principle : NDIR (Dual Beam)

Detection range : 0 to 100 Vol.-% (SM-CDX)

Accuracy : < 1 % of range Operating

temperature : -10 C to 50C

Pressure : 800 hPa to 1100 hPa

Humidity : 0% to 95% rel. humidity

Warm up time : < 2 Min.

Response time : < 25 s Diffusion , < 5 s Flow

Operating voltage : 5,0 V DC +/- 5 %

Drive current : 70mA (switch on current approx. 140mA) Outputs : 2 Signal outputs (Open collector),

                Modbus Open Protocol


Infrared Gas Sensor Module for Methane, CO2

More details >> 

Gas sensor with infrared detection technology (NDIR) Dual Beam Highly reliable LEL monitorring Settable alarm thresholds Bus-capable (modbusprotocol) Lifetime > 10 Years General features

Gas detected : Methane CH4

Detection principle : NDIR (Dual Beam)

Detection range : 0 to 100 Vol.-% (SM-MAX)

Accuracy : < 1 % of range Operating

Temperature : -10C to 50C

Pressure : 800 hPa to 1100 hPa

Humidity : 0% to 95% rel. humidity

Warm up time : < 2 Min.

Response time : < 25 s Diffusion , < 5 s Flow

Operating voltage : 5,0 V DC +/- 5 %

Drive current : 70mA (switch on current approx. 140mA) 

Outputs : 2 Signal outputs (Open collector), Modbus Open

                Protocol


New Biogas Analyser (GasMaster Z92)

Bht 200,000.00

Quantity:   

New Biogas Analyser (GasMaster Z92)

The Polysource's GasMaster NDIR double-gases module is a universal, pump-priming gas sensor, which detects CO2, CH4 with the non-dispersive infra-red (NDIR) principal. It is oxygen non-addicted with the advantages of good selectivity and long life. Temperature compensation is available as the temperature sensor internal.
The gas sensor owns both UART output, simulate voltage output, easy to operate.
GasMaster Biogas Analyser Z92 is a universal infrared gas sensor made up of mature infrared absorption gas detection technology, precision optics design, superior circuit design, which can be wildly used in rural areas for methane detection, Biogas Plant, Industrial process, Security protection & monitoring, Biogas Upgrading to Bio-Methane.


Portable H2S Monitor for Biogas T84 Series

More Details >>>>

Polysource Co.,Ltd. THAILAND Tel. +66(0) 29792982-3 Fax. +66 0-29792984 Email. a029792982@Gmail.com

Polysource Co.,Ltd. 124/42 Moo 1, Banklang, Muang, Pathumtani 12000  Tel. +66(0) 29792982-3  Fax. +66 (0) 29792984   Email. a029792982@Gmail.com
replicas breitling
replicas relojes lujo
replicas de relojes